INPUT_PARAMETERS
#Parameters (1.General)
pseudo_dir          ./
ntype               1
nbands              600
pseudo_type         upf
gamma_only          1
calculation         md
symmetry            0
out_level           m

#Parameters (2.SCF)
ecutwfc             60
scf_thr             1e-6
scf_nmax            100

#Parameters (3.Basis)
basis_type          lcao
ks_solver           genelpa

#Parameters (4.Smearing)
smearing_method     gaussian
smearing_sigma      0.02

#Parameters (5.Mixing)
mixing_type         pulay
mixing_beta         0.4
chg_extrap          second-order

#Parameters (6.MD)
md_nstep            10   // md steps
md_type             1    // choose ensemble
md_dt               1    // time step
md_tfirst           700  // the first target temperature
md_restart          0    // whether restart md
md_dumpfreq         10   // The period to dump MD information

These MD parameters means that ABACUS will use NVT ensemble with Nosé-hoover chain themostat; the time step is 1fs, and target temperature is 700K; start new MD without restart file.

Note: Please turn off symmetry during MD simulations.

The STRU file is:

ATOMIC_SPECIES
Sn 118.71  ./Sn.pz-bhs.UPF 

LATTICE_CONSTANT
23.45378

NUMERICAL_ORBITAL
./Sn_pz-bhs_8.0au_16Ry_2s2p1d

LATTICE_VECTORS
1.00     0.00     0.00
0.00     1.00     0.00
0.00     0.00     1.00

ATOMIC_POSITIONS
Direct 

Sn
0.0
64
0    0   0   1   1   1
0    0.25    0.25    1   1   1
0.25    0   0.25    1   1   1
0.25    0.25    0   1   1   1
0.375    0.125   0.375   1   1   1
0.125    0.125   0.125   1   1   1
0.125    0.375   0.375   1   1   1
0.375    0.375   0.125   1   1   1
0.5    0   0   1   1   1
0.5    0.25    0.25    1   1   1
0.75    0   0.25    1   1   1
0.75    0.25    0   1   1   1
0.875    0.125   0.375   1   1   1
0.625    0.125   0.125   1   1   1
0.625    0.375   0.375   1   1   1
0.875    0.375   0.125   1   1   1
0    0.5 0   1   1   1
0    0.75    0.25    1   1   1
0.25    0.5 0.25    1   1   1
0.25    0.75    0   1   1   1
0.375    0.625   0.375   1   1   1
0.125    0.625   0.125   1   1   1
0.125    0.875   0.375   1   1   1
0.375    0.875   0.125   1   1   1
0.5    0.5 0   1   1   1
0.5    0.75    0.25    1   1   1
0.75    0.5 0.25    1   1   1
0.75    0.75    0   1   1   1
0.875    0.625   0.375   1   1   1
0.625    0.625   0.125   1   1   1
0.625    0.875   0.375   1   1   1
0.875    0.875   0.125   1   1   1
0    0   0.5 1   1   1
0    0.25    0.75    1   1   1
0.25    0   0.75    1   1   1
0.25    0.25    0.5 1   1   1
0.375    0.125   0.875   1   1   1
0.125    0.125   0.625   1   1   1
0.125    0.375   0.875   1   1   1
0.375    0.375   0.625   1   1   1
0.5    0   0.5 1   1   1
0.5    0.25    0.75    1   1   1
0.75    0   0.75    1   1   1
0.75    0.25    0.5 1   1   1
0.875    0.125   0.875   1   1   1
0.625    0.125   0.625   1   1   1
0.625    0.375   0.875   1   1   1
0.875    0.375   0.625   1   1   1
0    0.5 0.5 1   1   1
0    0.75    0.75    1   1   1
0.25    0.5 0.75    1   1   1
0.25    0.75    0.5 1   1   1
0.375    0.625   0.875   1   1   1
0.125    0.625   0.625   1   1   1
0.125    0.875   0.875   1   1   1
0.375    0.875   0.625   1   1   1
0.5    0.5 0.5 1   1   1
0.5    0.75    0.75    1   1   1
0.75    0.5 0.75    1   1   1
0.75    0.75    0.5 1   1   1
0.875    0.625   0.875   1   1   1
0.625    0.625   0.625   1   1   1
0.625    0.875   0.875   1   1   1
0.875    0.875   0.625   1   1   1

The KPT file is:

K_POINTS
0
Gamma
1 1 1 0 0 0

Run the program, and see results in the output directory. The following files are about MD:

MD information can be found in file running_md.log.

------------------------------------------------------------------------------------------------
Energy              Potential           Kinetic             Temperature         Pressure (KBAR)     
-7.7824215          -7.782469           +4.7502231e-05      +10                 +124.19599          
------------------------------------------------------------------------------------------------

All energy values are in atomic unit (Ry), and temperature is Kelvin.